Envíos gratis a partir de 300,00€ a la Península e Islas Baleares.

(+34) 919 603 603 | [email protected]

Leica Geosystems
Leica Geosystems

Omni Tilt Sensor Node

Omni Tilt Sensor Node. Monitoring of the tilt condition of infrastructure such as retaining walls, support columns and river embankments.

Request more information

    Omni Tilt Sensor Node

    From the first level of data conversion, the movement at one end of a beam or cross member can be monitored, making it possible to detect phenomena such as landslides or railway track deformation.

    Thanks to our latest mathematical model, it is possible to accurately calculate the horizontal convergence of an underground railway tunnel comprising 6 segments.

    Type 6305 – WiSenMeshWAN® Omni Tilt Sensor Node
    Basic features
    Battery power supply1 primary 3.6 V type D lithium battery unit (ER34615)
    Accuracy cut-off voltage2.7 VDC
    Mesh network cut-off voltage2.1 VDC
    Battery connectionStandard aluminium battery holder
    Operating current (DC)Max. 65 mA (typically 50 mA)
    Local storageMinimum of 450 messages during mesh connection
    Dimensions (L x W x H)80 x 75 x 57 mm
    Weight0.43 kg
    Main sensor
    Sensor typeTilt values on the X, Y and Z axes
    Range-90° to +90°
    Accuracy0.002° (7.2″ or 0.0349 mm/m) within the range [-2.0°, 2.0°]
    Better than 0.01° (36″ or 0.1745 mm/m) at any angle within the range (-90°, 90°)
    Resolution0.0001° (0.36″ or 0.001745 mm/m)
    Standard system parameters
    TemperatureRange: -40 to 85°C; accuracy: ±1°C (typically 0.5°C); resolution: 0.1°C
    VoltageAccuracy: ±0.1 V
    WSN interface
    Wireless mesh interfaceWiSenMeshWAN® protocol
    Orientation for tilt measurement
    1. When holding the specification sheet horizontally, if the X-axis arrow rotates into the plane of the paper around point 0, the “x” value decreases. The same principle applies to the Y and Z axes.
    2. The node must be rigidly secured to ensure accurate measurements. Any movement in the mounting will affect the results.
    3. Omni Tilt Sensor Nodes must be positioned so that two of their marked axes are parallel to the horizontal plane, making the data easier to interpret.

    Designed for up to 10 years of maintenance-free operation, the units have an IP65 or higher protection rating and feature internal power supplies and radios. Thanks to their robust industrial enclosures, they can be installed in multiple ways to meet the different requirements of monitoring projects.

    1